    APPLICATION OF THE INTERCEPTOR WASTEWATER DRAG EQUATION AND DISPERSION MODELING TO DETERMINE ODOR CONTROL DESIGN PARAMETERS FOR A SYSTEM OF JUNCTION BOXES
    Access Water
    Water Environment Federation
    December 22, 2018
    June 3, 2025
    https://www.accesswater.org/?id=-293180
    Chicago Back (from Chicago)
    Alan E. Davis# S.Edwini-Bonsu. APPLICATION OF THE INTERCEPTOR WASTEWATER DRAG EQUATION AND DISPERSION MODELING TO DETERMINE ODOR CONTROL DESIGN PARAMETERS FOR A SYSTEM OF JUNCTION BOXES. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 3, 2025. https://www.accesswater.org/?id=-293180.
    MLA Back (from MLA)
    Alan E. Davis# S.Edwini-Bonsu. APPLICATION OF THE INTERCEPTOR WASTEWATER DRAG EQUATION AND DISPERSION MODELING TO DETERMINE ODOR CONTROL DESIGN PARAMETERS FOR A SYSTEM OF JUNCTION BOXES. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 3 Jun. 2025. <https://www.accesswater.org?id=-293180>.
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Start of menu
Description: Access Water
Context Menu
Description: Book cover
APPLICATION OF THE INTERCEPTOR WASTEWATER DRAG EQUATION AND DISPERSION MODELING TO DETERMINE ODOR CONTROL DESIGN PARAMETERS FOR A SYSTEM OF JUNCTION BOXES
  • Browse
  • CompilationsToggle child pages
    • Compilations list
  • Subscriptions
Tools
End of menu
Start of menu

Related contents

Loading related content
End of menu
Start of menu

Workflow

No linked records yet

X
  • Current: 2022-06-14 20:22:14 Adam Phillips
  • 2022-06-14 20:22:13 Adam Phillips
  • 2020-03-27 00:04:25 Adam Phillips
  • 2020-01-31 19:41:15 Administrator
  • 2020-01-31 19:41:14 Administrator
End of menu
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
APPLICATION OF THE INTERCEPTOR WASTEWATER DRAG EQUATION AND DISPERSION MODELING TO DETERMINE ODOR CONTROL DESIGN PARAMETERS FOR A SYSTEM OF JUNCTION BOXES

APPLICATION OF THE INTERCEPTOR WASTEWATER DRAG EQUATION AND DISPERSION MODELING TO DETERMINE ODOR CONTROL DESIGN PARAMETERS FOR A SYSTEM OF JUNCTION BOXES

APPLICATION OF THE INTERCEPTOR WASTEWATER DRAG EQUATION AND DISPERSION MODELING TO DETERMINE ODOR CONTROL DESIGN PARAMETERS FOR A SYSTEM OF JUNCTION BOXES

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
APPLICATION OF THE INTERCEPTOR WASTEWATER DRAG EQUATION AND DISPERSION MODELING TO DETERMINE ODOR CONTROL DESIGN PARAMETERS FOR A SYSTEM OF JUNCTION BOXES
Abstract
The Trinity River Authority of Texas (Authority) owns and operates the Central Regional WastewaterSystem (CRWS), a large regional system serving over 1 million people in 20 cities in the north Texas area. The Authority's 200-mile regional collection network delivers wastewater flows to a 162-million gallon per day (MGD) advanced secondary treatment plant located in Grand Prairie.The Authority has begun construction of two, large-diameter, relief interceptors that will serve the CRWS wastewater treatment plant (WWTP). These interceptors, the West Fork Relief Interceptor WF-1 and the Elm Fork Relief Interceptor EF-1, along with four existing interceptors, will serve themain influent pump stations at the WWTP. A new junction box, JB 1E, is being constructed outside the plant levee to serve the WF-1 line. A second box, JB 1F, is being constructed to serve the EF-1line and will be interconnected to JB 1E. Two boxes currently exist, JB 1C (above grade) and JB 1D(below grade and well-sealed). As part of this paper, the remaining capacity of the existing foul air collection system (F.A.C.S.) is presented and compared to the projected airflows from JB 1E and JB 1F. Airflows and odorant concentrations were evaluated for both JB 1F and 1E, and design recommendations were made for odor treatment.Airflows for junction box structures JB 1C, JB 1E, and JB 1F were calculated by determining the airflows expected from the sewer headspace and adding a suitable airflow to provide for a slight vacuum within the box under normal conditions, preventing the escape of odorous emissions. When construction is complete, there will be four junction boxes at the WWTP influent area, each interconnected to the others; therefore, the influent area was approached as one large system. After construction is complete on WF-1, there will be 2 — 102” diameter, 2 — 72” diameter, and 2-108” diameter interceptors carrying flow (and foul air) into the junction boxes. Both wastewater and air will flow co-currently into the junction box system.This paper presents the methods for addressing odor control needs for the new junction box structures currently being constructed. At the completion of construction, tests will be performed to determine if the predicted airflows were adequate to contain volume of air entering the boxes from the interceptors. Additional tests will be performed to determine if the odorant concentration in the foul air stream is within the parameters given during design.Airflows were calculated assuming each pipe flowed approximately 42-percent full and the headspaceair velocity was approximately 37-percent of the liquid flow velocity. Airflow calculations were made using a wastewater drag equation for laminar flow proposed by Edwini- Bonsu and Steffler (2004)Foul air quality was developed using test data collected on the existing JB 1C. A logging hydrogen sulfide data collector was placed inside JB 1C for two weeks (August 3, 2004 through August 17, 2004) to determine approximate H2S levels for design. The logger showed an average H2S concentration of 300 ppm with peaks over 1,000 ppm for the period between August 7 and August 17. Reduced sulfur compounds were not monitored but were expected to be present in concentrations sufficient to be perceptible offsite. For design purposes, hydrogen sulfide concentrations entering the odor treatment unit were expected to average 300 ppm with daily peaks up to 700 ppm and occasional peaks over 1,000 ppm, with seasonal and daily variations. In addition to H2S, the odor treatment unit was designed to treat other, non-H2S odors that would typically be present in raw, septic wastewater. Foul air dispersion modeling was conducted to determine the acceptable level of treatment. Model results indicated that the primary odor impact appears to be due to hydrogen sulfide emissions at the junction box area.To reduce initial capital costs, a treatment system was designed for H2S removal only, with provisions made for future addition of a polishing component for treating other odor causing compounds. A 10,000 cfm bioscrubber was designed to treat odors from the bioscrubber area. The existing biofilter system was utilized to treat an additional 5000 cfm from the system.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
The Trinity River Authority of Texas (Authority) owns and operates the Central Regional WastewaterSystem (CRWS), a large regional system serving over 1 million people in 20 cities in the north Texas area. The Authority's 200-mile regional collection network delivers wastewater flows to a 162-million gallon per day (MGD) advanced secondary treatment plant located in Grand Prairie.The Authority has...
Author(s)
Alan E. DavisS.Edwini-Bonsu
SourceProceedings of the Water Environment Federation
SubjectSession 7: Fate and Odor Modeling
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2006
ISSN1938-6478
SICI1938-6478(20060101)2006:3L.607;1-
DOI10.2175/193864706783791326
Volume / Issue2006 / 3
Content sourceOdors and Air Pollutants Conference
First / last page(s)607 - 621
Copyright2006
Word count686

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'APPLICATION OF THE INTERCEPTOR WASTEWATER DRAG EQUATION AND DISPERSION MODELING TO DETERMINE ODOR CONTROL DESIGN PARAMETERS FOR A SYSTEM OF JUNCTION BOXES'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
APPLICATION OF THE INTERCEPTOR WASTEWATER DRAG EQUATION AND DISPERSION MODELING TO DETERMINE ODOR CONTROL DESIGN PARAMETERS FOR A SYSTEM OF JUNCTION BOXES
Pricing
Non-member price: $11.50
Member price:$9.50
-293180
Get access
-293180
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'APPLICATION OF THE INTERCEPTOR WASTEWATER DRAG EQUATION AND DISPERSION MODELING TO DETERMINE ODOR CONTROL DESIGN PARAMETERS FOR A SYSTEM OF JUNCTION BOXES'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Start of menu

Details

Description: Book cover
APPLICATION OF THE INTERCEPTOR WASTEWATER DRAG EQUATION AND DISPERSION MODELING TO DETERMINE ODOR CONTROL DESIGN PARAMETERS FOR A SYSTEM OF JUNCTION BOXES
Abstract
The Trinity River Authority of Texas (Authority) owns and operates the Central Regional WastewaterSystem (CRWS), a large regional system serving over 1 million people in 20 cities in the north Texas area. The Authority's 200-mile regional collection network delivers wastewater flows to a 162-million gallon per day (MGD) advanced secondary treatment plant located in Grand Prairie.The Authority has begun construction of two, large-diameter, relief interceptors that will serve the CRWS wastewater treatment plant (WWTP). These interceptors, the West Fork Relief Interceptor WF-1 and the Elm Fork Relief Interceptor EF-1, along with four existing interceptors, will serve themain influent pump stations at the WWTP. A new junction box, JB 1E, is being constructed outside the plant levee to serve the WF-1 line. A second box, JB 1F, is being constructed to serve the EF-1line and will be interconnected to JB 1E. Two boxes currently exist, JB 1C (above grade) and JB 1D(below grade and well-sealed). As part of this paper, the remaining capacity of the existing foul air collection system (F.A.C.S.) is presented and compared to the projected airflows from JB 1E and JB 1F. Airflows and odorant concentrations were evaluated for both JB 1F and 1E, and design recommendations were made for odor treatment.Airflows for junction box structures JB 1C, JB 1E, and JB 1F were calculated by determining the airflows expected from the sewer headspace and adding a suitable airflow to provide for a slight vacuum within the box under normal conditions, preventing the escape of odorous emissions. When construction is complete, there will be four junction boxes at the WWTP influent area, each interconnected to the others; therefore, the influent area was approached as one large system. After construction is complete on WF-1, there will be 2 — 102” diameter, 2 — 72” diameter, and 2-108” diameter interceptors carrying flow (and foul air) into the junction boxes. Both wastewater and air will flow co-currently into the junction box system.This paper presents the methods for addressing odor control needs for the new junction box structures currently being constructed. At the completion of construction, tests will be performed to determine if the predicted airflows were adequate to contain volume of air entering the boxes from the interceptors. Additional tests will be performed to determine if the odorant concentration in the foul air stream is within the parameters given during design.Airflows were calculated assuming each pipe flowed approximately 42-percent full and the headspaceair velocity was approximately 37-percent of the liquid flow velocity. Airflow calculations were made using a wastewater drag equation for laminar flow proposed by Edwini- Bonsu and Steffler (2004)Foul air quality was developed using test data collected on the existing JB 1C. A logging hydrogen sulfide data collector was placed inside JB 1C for two weeks (August 3, 2004 through August 17, 2004) to determine approximate H2S levels for design. The logger showed an average H2S concentration of 300 ppm with peaks over 1,000 ppm for the period between August 7 and August 17. Reduced sulfur compounds were not monitored but were expected to be present in concentrations sufficient to be perceptible offsite. For design purposes, hydrogen sulfide concentrations entering the odor treatment unit were expected to average 300 ppm with daily peaks up to 700 ppm and occasional peaks over 1,000 ppm, with seasonal and daily variations. In addition to H2S, the odor treatment unit was designed to treat other, non-H2S odors that would typically be present in raw, septic wastewater. Foul air dispersion modeling was conducted to determine the acceptable level of treatment. Model results indicated that the primary odor impact appears to be due to hydrogen sulfide emissions at the junction box area.To reduce initial capital costs, a treatment system was designed for H2S removal only, with provisions made for future addition of a polishing component for treating other odor causing compounds. A 10,000 cfm bioscrubber was designed to treat odors from the bioscrubber area. The existing biofilter system was utilized to treat an additional 5000 cfm from the system.
The Trinity River Authority of Texas (Authority) owns and operates the Central Regional WastewaterSystem (CRWS), a large regional system serving over 1 million people in 20 cities in the north Texas area. The Authority's 200-mile regional collection network delivers wastewater flows to a 162-million gallon per day (MGD) advanced secondary treatment plant located in Grand Prairie.The Authority has...
Author(s)
Alan E. DavisS.Edwini-Bonsu
SourceProceedings of the Water Environment Federation
SubjectSession 7: Fate and Odor Modeling
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2006
ISSN1938-6478
SICI1938-6478(20060101)2006:3L.607;1-
DOI10.2175/193864706783791326
Volume / Issue2006 / 3
Content sourceOdors and Air Pollutants Conference
First / last page(s)607 - 621
Copyright2006
Word count686
End of menu
Start of menu

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task
End of menu

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Alan E. Davis# S.Edwini-Bonsu. APPLICATION OF THE INTERCEPTOR WASTEWATER DRAG EQUATION AND DISPERSION MODELING TO DETERMINE ODOR CONTROL DESIGN PARAMETERS FOR A SYSTEM OF JUNCTION BOXES. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 3 Jun. 2025. <https://www.accesswater.org?id=-293180CITANCHOR>.
Alan E. Davis# S.Edwini-Bonsu. APPLICATION OF THE INTERCEPTOR WASTEWATER DRAG EQUATION AND DISPERSION MODELING TO DETERMINE ODOR CONTROL DESIGN PARAMETERS FOR A SYSTEM OF JUNCTION BOXES. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 3, 2025. https://www.accesswater.org/?id=-293180CITANCHOR.
Alan E. Davis# S.Edwini-Bonsu
APPLICATION OF THE INTERCEPTOR WASTEWATER DRAG EQUATION AND DISPERSION MODELING TO DETERMINE ODOR CONTROL DESIGN PARAMETERS FOR A SYSTEM OF JUNCTION BOXES
Access Water
Water Environment Federation
December 22, 2018
June 3, 2025
https://www.accesswater.org/?id=-293180CITANCHOR